Sometimes the LSI controllers are not set up for automatic rebuilds. Steps performed via storcli after an improperly removed device:
storcli /c0 show to identify the disk
PD LIST :
---------------------------------------------------------------------------------
EID:Slt DID State DG Size Intf Med SED PI SeSz Model Sp Type
---------------------------------------------------------------------------------
252:0 9 Onln 0 223.062 GB SATA SSD N N 512B INTEL SSDSC2KB240G7 U -
252:1 8 UBad - 223.062 GB SATA SSD N N 512B INTEL SSDSC2BB240G4 U -
---------------------------------------------------------------------------------
storcli /c0/e252/s1 set good to change status from bad to good
Drive Information :
---------------------------------------------------------------------------------
EID:Slt DID State DG Size Intf Med SED PI SeSz Model Sp Type
---------------------------------------------------------------------------------
252:0 9 Onln 0 223.062 GB SATA SSD N N 512B INTEL SSDSC2KB240G7 U -
252:1 8 UGood F 223.062 GB SATA SSD N N 512B INTEL SSDSC2BB240G4 U -
---------------------------------------------------------------------------------
storcli /c0/e252/s1 insert dg=0 array=0 row=1 to insert disk to array 0
...
Controller = 0
Status = Success
Controller = 0
Status = Success
Description = Insert Drive Succeeded.
storcli /c0/e252/s1 start rebuild initiate the rebuild
Controller = 0
Status = Success
Description = Start Drive Rebuild Succeeded.
storcli /c0/e252/s1 show rebuild
Status = Success
Status = Success
Description = Show Drive Rebuild Status Succeeded.
------------------------------------------------------
Drive-ID Progress% Status Estimated Time Left
------------------------------------------------------
/c0/e252/s1 0 In progress 0 Seconds
------------------------------------------------------